System Integration

PLC, SCADA & DCS Integration

SentinelAI connects directly to your existing automation infrastructure. No proprietary controllers, no rip-and-replace. Plug into the safety circuit of any industrial control system.

Integration Methods

Four ways to connect

Universal — Recommended

Dry Contact Relay Output

Hardware relay — works with every PLC ever made

SentinelAI provides a normally-closed (NC) dry contact relay output. Wire it directly in series with your existing E-STOP circuit. When a human is detected, the relay opens — triggering an emergency stop exactly like a physical mushroom button. No software, no protocol, no compatibility issues.

NC / NO configurable24VDC / 220VAC rated10A contact ratingSeries with E-STOP circuit
Industrial Ethernet

Modbus TCP / EtherNet-IP

MODBUS TCP  ·  EtherNet/IP

SentinelAI exposes a Modbus TCP server. The PLC reads detection status, zone states, and alarm codes as register values in real time. Full bidirectional communication — read zone status, write zone enable/disable from the PLC.

Modbus TCP serverEtherNet/IP adapterAllen-Bradley compatibleSchneider compatible
Siemens

PROFINET / PROFIBUS

PROFINET IO  ·  PROFIBUS DP

SentinelAI supports PROFINET IO device mode for direct integration with Siemens SIMATIC S7-300/400/1200/1500 series PLCs. The system appears as a PROFINET IO device in TIA Portal. GSDML file provided.

PROFINET IO deviceGSDML file providedS7-300/400/1200/1500TIA Portal compatible
SCADA / DCS

OPC-UA Server

OPC-UA  ·  REST API

SentinelAI runs an embedded OPC-UA server. All zone states, detection events, and system health metrics are available as OPC-UA nodes — subscribable by any SCADA client (WinCC, Wonderware, Ignition). A REST API is also available for custom integrations.

OPC-UA serverWinCC compatibleIgnition compatibleREST API
Signal Flow

How the signal reaches your PLC

Dry Contact Relay Integration (Universal Method)

📷IP CameraRTSP stream
LAN
🧠Detection PCAI Detection
USB/GPIO
🔌Relay ModuleNC contact
24VDC wire
🎛️PLC InputSafety circuit
PLC logic
🛑E-STOP<200ms total
Compatibility

Tested PLC & SCADA platforms

ManufacturerPlatformIntegration methodCompatibilityNotes
SiemensSIMATIC S7-1200/1500PROFINET IO + RelayFullGSDML file provided. TIA Portal add-in available.
SiemensSIMATIC S7-300/400Relay + Modbus TCPFullVia CP 343-1/443-1 Ethernet module.
Allen-BradleyControlLogix / CompactLogixEtherNet/IP + RelayFullAdd-On Instruction (AOI) provided for Studio 5000.
SchneiderModicon M340/M580Modbus TCP + RelayFullUnity Pro / EcoStruxure compatible.
MitsubishiMELSEC iQ-R / Q SeriesRelay + SLMP/ModbusFullGX Works3 sample program available.
ABBAC500 / 800xA DCSModbus TCP + OPC-UAFullOPC-UA integration for 800xA SCADA.
Any brandAny PLC with DIDry contact relayUniversalNC relay wires into any digital input or E-STOP chain.

Don't see your PLC?

Contact us with your PLC model and we'll confirm integration compatibility within 24 hours.

Check Compatibility